Technical Articles
MIL-DTL-5015 Insert Arrangements: Identify the Layout You Need
2026-10-31T09:06:00.000Z
Identify a 5015-style layout using shell/arrangement, contacts, polarization and the correct viewing direction. See why counting visible contacts is not enough.
To identify a MIL-DTL-5015-style insert arrangement, obtain the complete shell-and-layout reference, the contact designation and the applicable drawing. Counting the visible contacts is a useful observation, but it cannot identify the full configuration on its own.
Be especially careful with an old equipment connector described only as “MS3106, four-pin.” The missing shell/arrangement, class and suffix may determine which item can actually be considered.

Figure 1. Original flanged supplier sample with seven visible pin contacts. The visible population is one identification input, not proof of a complete MS ordering code.
The arrangement reference is a lookup key
The Amphenol 97 catalog includes common 5015-style layout references. Three examples make the naming problem clear: [1]
| Catalog layout example | Contact count in that catalog's diagram | Reading lesson |
|---|---|---|
| 12S-3 | Two | The final digit does not simply state the population |
| 14S-2 | Four | Keep the shell and arrangement together |
| 16S-1 | Seven | A short suffix alone cannot identify the face |
These are examples from a manufacturer's commercial-family catalog. They help explain layout identification; they do not establish that any offered military-reference item has a particular maker, qualification or complete installation configuration.
For an actual MS3106A22-14S requirement, preserve “22-14” as the shell/arrangement reference within the full number. Do not translate “14” into an assumed contact count. Obtain the relevant diagram and document which arrangement is being offered.
View the interface from the specified side
An unlabeled front photograph can create a false match when compared with a rear-view wiring image. Record the drawing's viewing convention and identify the sample view before comparing cavity locations or reference features.
Ask for a mating-face image taken square to the interface, a side marking view and, where relevant, a separately labelled rear view. Include a scale reference for overall identification when practical, while keeping dimensional acceptance tied to the drawing.
Do not derive a circuit assignment from contact positions in a product photograph. The controlled wiring document must identify the circuits and cavities for the actual assembly.

Figure 2. A different flanged supplier sample showing three visible pin contacts. Comparing real faces helps prevent treating an arrangement suffix as a universal contact-count rule.
Check more than the pattern
Once a layout candidate has been found, complete a second pass:
- Family and body: establish the actual connector reference and mounting form.
- Contacts: verify the pin/socket designation and the contact specification.
- Polarization: retain the normal or alternate position required by the full reference.
- Termination and rear configuration: identify what is being supplied and how it joins the harness.
- Electrical requirements: compare the circuit conditions with the applicable component information through the responsible designer.
This article does not assign a universal current rating to a layout. Contact size, circuit requirements and the relevant operating conditions require their own evidence. The number of visible contacts is not a current-rating label.
When the old marking is missing
Use the identification request to separate known observations from proposed conclusions. For example:
“Existing equipment receptacle; marking unreadable. Mating-face and side images attached. Panel drawing attached. Circuit schedule contains the conductor requirements. Please identify candidate configurations and list any unresolved fields before quotation.”
That request is more useful than inventing a full MS number from the appearance. It also allows a supplier to say which evidence is still needed without disguising a tentative identification as an approved replacement.

Figure 3. Orion service-module bulkhead undergoing cable-harness processing at Kennedy, 20 September 2013. The surrounding installation is useful context, while the actual cavity assignment still comes from its controlled wiring document. Credit: NASA/KSC. Original archive. Context only; the connector series is not identified and this is not a Tradin installation or endorsement.
What to send for quotation
Include the complete original reference where available, both mating references, the applicable drawing, quantity and required arrival date. Add whether contacts, rear hardware and specified documents must be included. State whether an evaluated alternative is acceptable or the order must use a named original item.
Browse the MIL-DTL-5015 sourcing range. For a mixed requirement containing other circular-connector families, keep a separate full reference and mating record for each line.
Submit the existing layout and installation evidence →
Reference
[1] Amphenol 97 Series catalog, 12-022-19, insert availability, arrangement diagrams and alternate-position information. Use the exact offered product drawing for purchase release. Checked 18 October 2026.
FAQ
Does the final number always identify the contact count?
No. The cited commercial 97 Series examples include 12S-3 with two contacts, 14S-2 with four and 16S-1 with seven. Use the applicable chart.
Can I wire a connector by copying a product photograph?
Use the controlled wiring document and specified viewing convention. A product photograph does not define a circuit-to-cavity assignment.
Can Tradin review an unidentified equipment connector?
Send the known markings, mating-face and side images, available drawing, quantity and installation requirements. Any unresolved identification fields must remain explicit.